A better home
starts with
the air.
Fresh air. Recovered warmth. Everyday comfort.
Discover whole-home ventilation designed to work beautifully behind the scenes.


Fresh thinking.
For everyday
living.
You put care into every part of a home.
The air inside deserves the same.
RENEO-400 supplies filtered fresh air to living spaces and extracts stale air from wet rooms, recovering useful warmth along the way. It is a considered choice for homes with higher ventilation duties and space for an upright unit.
Select against calculated airflow and system resistance. Maximum airflow is not available at every pressure; final suitability depends on the complete system design.
Comfort comes
as standard.
Useful warmth retained. Incoming air filtered. Moisture considered. The fundamentals are already part of the specification.
Keep more
of the warmth.
A counterflow heat exchanger recovers energy from outgoing air, helping reduce the heat lost through ventilation.
F7Fresh air.
Filtered first.
F7 supply filtration is standard, filtering incoming airborne particles before air reaches living spaces.
Humidity Sensor
Built-in.
Humidity sensing helps manage moisture from bathing, cooking and day-to-day life, without specifying an add-on humidity sensor.
1. Up to 93% catalogue heat recovery. Actual performance depends on operating conditions. Independent test results are shown separately below.
Your home.
Your rhythm.
Ventilation that fits the way you live.
Use the Blauberg Home app to plan ventilation around your routine, respond when more airflow is needed and keep track of filter maintenance.
- Set a weekly schedule. Match operation to the household routine.
- Boost when needed. Access everyday controls from your phone.
- Stay informed. Filter reminders and alarm indication help you keep on top of maintenance.
- Let cooler air be useful. Summer bypass avoids unnecessary heat recovery when conditions allow. It is not active cooling.

Better air.
A shared ambition.
Different priorities. One carefully considered system. Choose your role to see what RENEO-400 brings to your project.
Your selected model.
F7 supply filtration, built-in humidity sensing and Wi-Fi app control are included. Here is the exact control specification for RENEO-400.
RENEO-400
RENEO (S71) connected control with operating data logging. A clear starting point for everyday whole-home ventilation.
- Controller
- RENEO (S71)
- Preheater
- Not included
- Modbus
- RTU
- Data logging
- Yes
- External-heater control
- No
- Max. total power
- 178 W
- Max. total current
- 1.4 A

Performance measured.
Confidence earned.
Independent testing puts numbers behind the promise. RENEO-400 reference results measure fan energy use and heat recovery. Use the data at the required duty and keep its scope clear.
at the 21 l/s test point · RENEO (S71)
at the 21 l/s test point · RENEO (S71)
RENEO-400 (S71) performance test results
Supplied test data · airflow at STP
| Kitchen + additional wet rooms | Airflow [l/s at STP] | Specific fan power [W/(l/s)] | Thermal efficiency [%] |
|---|---|---|---|
| 1 | 21.0 | 0.51 | 92.6 |
| 2 | 29.0 | 0.54 | 92.2 |
| 3 | 37.0 | 0.61 | 91.6 |
| 4 | 45.0 | 0.71 | 91.1 |
| 5 | 53.0 | 0.87 | 90.5 |
| 6 | 61.0 | 1.09 | 89.7 |
| 7 | 69.0 | 1.37 | 88.9 |
Swipe across to see all columns →
Supplied RENEO (S71) test sheet. Results are not established for the S / SE variants. SAP method and PCDB status are not stated. Test values and catalogue heat recovery are separate data.
Find your design duty.
Open full-size curve

Quietly working.
Carefully planned.
Give ventilation a considered place in the project: a dedicated cupboard, utility room, plant area or suitable loft location. Wall or floor mounting allows the unit position to follow the design.
Plan the 160 mm duct routes, attenuation, condensate drainage and maintenance access together.
Coordinate your installationReady for the drawing board.
Dimensions and specifications for RENEO-400. Control and total electrical ratings appear in your selected-model section above.

- Ø D
- 160 mm
- H
- 880 mm
- H1
- 939 mm
- L
- 616 mm
- L1
- 230 mm
- W
- 770 mm
- W1
- 355 mm
- Weight
- 26 kg
Mounting & maintenance access
Wall or floor mounting. Keep cover, filter and heat-exchanger access clear. Floor supports must provide at least 150 mm for condensate drainage. Confirm port positions and clearances in the model manual.
- Maximum airflow
- 124 l/s
- Catalogue heat recovery
- Up to 93%
- Duct connections
- 160 mm
- Mounting
- Wall or floor
- Supply filter
- F7 standard
- Extract filter
- G4
- Humidity Sensor Built-in
- Yes
- Summer bypass
- Yes
- Electrical supply
- 230 V, 50/60 Hz
- Maximum fan power
- 178 W
- SEC class
- A+
- UK arrangement
- Left-hand
- Casing / insulation
- EPP / 45 mm
- Heat exchanger
- Counterflow polystyrene
- Indoor ambient
- +1 to +40°C; max. 60% RH, non-condensing
- Transported air
- −25 to +40°C
Acoustic performance · at 70% airflow
LpA
LwA
LpA uses spherical free-field conditions. Installed room noise depends on operating duty, location and attenuation.
The right finishing touches.
Plan controls, attenuation and drainage alongside the unit. Keep the correct replacement filters on the maintenance schedule.

F7 supply filter
FP-496-150-60-F7Replacement for the standard supply filter.

G4 extract filter
FP-496-150-60-G4Replacement extract filter.

LCD wall control
S25Optional wired touch-screen panel.

Wall control
S22Optional wired panel.

CO₂ sensor
CD-3Optional demand-control sensor.

Duct silencer
SD-160-600600 mm long; reduces duct noise.

Condensate trap
SFK 20x32Syphon kit for condensate drainage.
Accessory images are illustrative. Confirm the exact model when ordering.
Lifestyle and loft images are illustrative AI-created visuals, not completed project photographs. Original product and accessory images are illustrative. Specifications and test scope follow the current UK brochure.